From cbe8a716f2b4bceb1a1a697d963a9ef28423c9f7 Mon Sep 17 00:00:00 2001 From: "cl349@firebug.cl.cam.ac.uk" Date: Wed, 18 May 2005 15:28:20 +0000 Subject: [PATCH] bitkeeper revision 1.1451 (428b5f14gpuT4COa88QnSJNe11X63A) XendDomain.py: Don't add domain to shutdown cleanup machinery when sending sysrq. Signed-off-by: Christian Limpach --- tools/python/xen/xend/XendDomain.py | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/tools/python/xen/xend/XendDomain.py b/tools/python/xen/xend/XendDomain.py index d503f7cc12..3140584884 100644 --- a/tools/python/xen/xend/XendDomain.py +++ b/tools/python/xen/xend/XendDomain.py @@ -469,7 +469,8 @@ class XendDomain: if reason == 'halt': reason = 'poweroff' val = dominfo.shutdown(reason, key=key) - self.add_shutdown(dominfo, reason, key) + if reason != 'sysrq': + self.add_shutdown(dominfo, reason, key) return val def add_shutdown(self, dominfo, reason, key): -- 2.30.2